Features
Become an Inventor Partner
Technical Specifications
- V4MFI - 24 / V4MF0 - 24
- Cooling Capacity 24.000 Btu / h
- Heating Capacity 26.000 Btu / h
- Cooling Capacity Range (7.500 - 26.500) Btu / h
- Cooling Capacity Range 7.03 (2.19 - 7.77) kWatt
- Heating Capacity (5.200 - 29.500) Btu / h
- Heating Capacity 7.62 (1.52 - 8.65) kWatt
-
Seasonal Efficiency(In accordance
to EN14825) Cooling - Pdesign 7.0 kW
- Energy Class Α++
- SEER 6.1
-
Seasonal Efficiency(In accordance
to EN14825) Heating Middle Zone - Pdesign 5.8 kW
- Energy Class Α+
- SCOP 4.0
-
Seasonal Efficiency(In accordance
to EN14825) Heating Warm Zone - Pdesign 5.5 kW
- Energy Class A+++
- SCOP 5.1
- EER / COP -
- Voltage / Frequency / Phase 230 / 50 / 1 V / Hz / Ph
- Current Input - Cooling 10.19 Α
- Current Input - Heating 9.2 Α
- Power Input - Cooling 2.345 W
- Power Input - Heating 2.117 W
- Air Flow Volume (High/Medium/Low) 1.230 / 1.080 / 978 m3 / h
- Noise Level - Indoor unit (Low/Medium/High) 43.5 / 46 / 49.5 dB (A)
- Noise Level - Outdoor unit 60.5 dB (A)
- Sound Power Level - Indoor/Outdoor unit 63 / 65 dB (A)
- Power Supply Wire Outdoor / Fuses 3 × 2.5 / 1 × 20 No x mm2 / Α
- Signal Wires 3 × 1.5 & (4 × 1.0 Shield) No x mm2
- Dimensions WxDxH - Indoor unit 500 × 315 × 1.700 mm
- Dimensions WxDxH - Outdoor unit 845 × 363 × 702 mm
- Net Weight - Indoor / Outdoor 37.5 / 49 kg
- Liquid line | Gas line 3 / 8” - 5 / 8”
- Refrigerant R410A / 1.950g
- Outdoor Operation Temperature Range - Cooling/Heating -15~50/ - 15~24 °C
- V4MFI - 50 / V4MF0 - 50
- Cooling Capacity 48.000 Btu / h
- Heating Capacity 50.000 Btu / h
- Cooling Capacity Range (13.500 - 51.000) Btu / h
- Cooling Capacity Range 14.07 (3.96 - 14.95) kWatt
- Heating Capacity (8.700 - 58.000) Btu / h
- Heating Capacity 14.65(2.43-17.0) kWatt
-
Seasonal Efficiency(In accordance
to EN14825) Cooling - Pdesign 14.0 kW
- Energy Class A++
- SEER 6.1
-
Seasonal Efficiency(In accordance
to EN14825) Heating Middle Zone - Pdesign 11.1 kW
- Energy Class Α+
- SCOP 4.0
-
Seasonal Efficiency(In accordance
to EN14825) Heating Warm Zone - Pdesign 11.6 kW
- Energy Class A+++
- SCOP 5.1
- EER / COP 2.81 / 3.30
- Voltage / Frequency / Phase 380 / 50 / 3 V / Hz / Ph
- Current Input - Cooling 8.8 Α
- Current Input - Heating 7.0 Α
- Power Input - Cooling 5.000 W
- Power Input - Heating 4.440 W
- Air Flow Volume (High/Medium/Low) 2.150/1.850 /1.450 m3 / h
- Noise Level - Indoor unit (Low/Medium/High) 44 / 48 / 53 dB (A)
- Noise Level - Outdoor unit 64 dB (A)
- Sound Power Level - Indoor/Outdoor unit 63 / 72 dB (A)
- Power Supply Wire Outdoor / Fuses 5 × 2.5 / 3 × 25 No x mm2 / Α
- Signal Wires 3 × 2.5 (2 × 0.5 Shield) No x mm2
- Dimensions WxDxH - Indoor unit 600 × 455 × 1.934 mm
- Dimensions WxDxH - Outdoor unit 952 × 415 × 1.333 mm
- Net Weight - Indoor / Outdoor 61.6 / 108.1 kg
- Liquid line | Gas line 3 / 8” - 5 / 8”
- Refrigerant R410A / 4.000g
- Outdoor Operation Temperature Range - Cooling/Heating -15~50/ - 25~30 °C
- V4MFI - 66 / V4MF0 - 66
- Cooling Capacity 53.000 Btu / h
- Heating Capacity 60.000 Btu / h
- Cooling Capacity Range (14.000 - 55.000) Btu / h
- Cooling Capacity Range 15.53 (4.10 - 16.12) kWatt
- Heating Capacity (14.500-63.000)+12.000 Btu / h
- Heating Capacity 17.58(4.25-18.46)+3.517 kWatt
-
Seasonal Efficiency(In accordance
to EN14825) Cooling - Pdesign 15.6 kW
- Energy Class A++
- SEER 6.0
-
Seasonal Efficiency(In accordance
to EN14825) Heating Middle Zone - Pdesign 12.3 kW
- Energy Class Α+
- SCOP 4.0
-
Seasonal Efficiency(In accordance
to EN14825) Heating Warm Zone - Pdesign 12.6 kW
- Energy Class A+++
- SCOP 5.1
- EER / COP 2.63 / 2.93
- Voltage / Frequency / Phase 380 / 50 / 3 V / Hz / Ph
- Current Input - Cooling 9.4 Α
- Current Input - Heating 10.7 Α
- Power Input - Cooling 6.200 W
- Power Input - Heating 6.000 W
- Air Flow Volume (High/Medium/Low) 2.150/1.850/1.450 m3 / h
- Noise Level - Indoor unit (Low/Medium/High) 44 / 48 / 52 dB (A)
- Noise Level - Outdoor unit 66 dB (A)
- Sound Power Level - Indoor/Outdoor unit 67 / 74 dB (A)
- Power Supply Wire Outdoor / Fuses 5 × 2.5 / 3 × 25 No x mm2 / Α
- Signal Wires 5 × 2.5 (2 × 0.5 Shield) No x mm2
- Dimensions WxDxH - Indoor unit 600 × 455 × 1.934 mm
- Dimensions WxDxH - Outdoor unit 952 × 415 × 1.333 mm
- Net Weight - Indoor / Outdoor 65.0 / 112.8 kg
- Liquid line | Gas line 3 / 8” - 5 / 8”
- Refrigerant R410A / 4.300g
- Outdoor Operation Temperature Range - Cooling/Heating 18~43/ - 7~24 °C
More
Elevata capacita' di riscaldamento anche a basse temperature -15°C
Il design ottimizzato e la tecnologia incorporata nell'unità esterna garantiscono il funzionamento efficiente ed efficace nella modalità di riscaldamento anche a -15°C.
Funzione Central control management (opzionale)
Il dispositivo multifunzionale centralizzato può controllare fino a 64 unità interne entro una lunghezza massima di collegamento di 1200 m.
Modalità di funzionamento Turbo
Questa funzione consente di aumentare la potenza di raffreddamento e di riscaldamento per un certo periodo e di conseguenza raffreddare o riscaldare rapidamente l'ambiente.
Funzione di Blocco
Attivare la funzione di blocco per impedire a chiunque di modificare le impostazioni o ai bambini di giocare con l'unità.
Telecomando Smart
Sfruttate le 4 possibilità di regolazione della velocità della ventola dell'unità interna e approfittate delle funzioni di promemoria per la pulizia del filtro e per la regolazione della posizione delle alette, del funzionamento del sensore per la compensazione della temperatura e delle varie impostazioni di temperatura creando le condizioni ideali nel vostro ambiente.
Media Library for Floor Standing
User & Installation Manuals - Energy Labels - Pdesign Test Report - High Resolution Photos